1. Academic Validation
  2. Quality assurance and quality control methods for animal and human applications of no-carrier-added 6-[18F]fluorodopa for PET investigations of dopaminergic systems

Quality assurance and quality control methods for animal and human applications of no-carrier-added 6-[18F]fluorodopa for PET investigations of dopaminergic systems

  • Appl Radiat Isot. 1993 Jul;44(7):993-8. doi: 10.1016/0969-8043(93)90001-q.
G N Reddy 1 M Haeberli H F Beer P Hasler A P Schubiger
Affiliations

Affiliation

  • 1 Division of Radiopharmacy, Paul Scherrer Institute, Villigen PSI, Switzerland.
Abstract

No-Carrier-Added (NCA) 6-[18F]fluoro-L-dopa (6-FDOPA) is being produced routinely for PET investigations of dopaminergic systems at our Institute. We describe here in detail the quality assurance methods involved in its multi-step developmental stage as a radiopharmaceutical. A method to remove toxic copper ions to prepare an injectable solution is described. The stability and shelf-life of NCA 6-FDOPA was also examined and results are discussed. Quality control involved three major aspects: (a) chemical purity, (b) radiochemical purity and (c) enantiomeric excess. A method for quick quality control of individual batch preparations is described.

Figures
Products
  • Cat. No.
    Product Name
    Description
    Target
    Research Area
  • HY-100705
    98.76%, No-carrier-added 6-[18F]fluoro-L-DOPA前体