  2. Development and validation of an LC-MS/MS method for quantification of Osimertinib and its two metabolites AZ7550 and AZ5104 in human plasma including long-time storage

Development and validation of an LC-MS/MS method for quantification of Osimertinib and its two metabolites AZ7550 and AZ5104 in human plasma including long-time storage

  • J Pharm Biomed Anal. 2025 Mar 15:255:116662. doi: 10.1016/j.jpba.2025.116662.
Eva Greibe 1 Boe Sorensen 2 Peter Meldgaard 3 Elke Hoffmann-Lücke 2
Affiliations

Affiliations

  • 1 Department of Clinical Biochemistry, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Health, Aarhus University, Aarhus, Denmark. Electronic address: evagreib@rm.dk.
  • 2 Department of Clinical Biochemistry, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Health, Aarhus University, Aarhus, Denmark.
  • 3 Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.
Abstract

Osimertinib (AZD9291) is a widely used tyrosine kinase inhibitor for the treatment of non-small cell lung Cancer patients with activating EGFR mutations. However, the correlation between dose and efficacy has been debated for several years. For this reason, there is a need for standardized methods for routine analysis, clinical studies on pharmacokinetics and dose-response relationships, and greater understanding of preanalytical conditions, such as sample storage stability. The objective of this study was to develop and validate a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of osimertinib and its two metabolites, AZ7550 and AZ5104, in human plasma and to investigate long-term storage stability of the analytes. Samples were prepared by protein precipitation and separated on a Kinetex EVO C18 column (2.1 × 150 mm, 2.6 µm). Electrospray ionization in positive mode and multiple reaction monitoring were used to monitor the ion transitions. The validated concentration ranges were from 1.25 to 3000 ng/mL. Interassay precisions and accuracies were all ≤ 15 %. Linearity, dilution integrity, and carry-over were also examined and satisfied the validation criteria. Stability was examined under different conditions, and the analytes were found to be stable for more than 3 years at -80°C (< 15 % decline). Finally, the analytical method was successfully applied in a clinical setting on plasma samples from 30 patients with non-small cell lung Cancer in treatment with osimertinib, demonstrating its suitability for use in clinical studies and its potential for therapeutic drug monitoring.

Keywords

AZ5104; AZ7550; High-performance liquid chromatography tandem mass spectrometry (LC-MS/MS); Osimertinib; Therapeutic drug monitoring.