1. Academic Validation
  2. An electrochemical signal-on apta-cyto-sensor for quantitation of circulating human MDA-MB-231 breast cancer cells by transduction of electro-deposited non-spherical nanoparticles of gold

An electrochemical signal-on apta-cyto-sensor for quantitation of circulating human MDA-MB-231 breast cancer cells by transduction of electro-deposited non-spherical nanoparticles of gold

  • J Pharm Biomed Anal. 2020 Jan 30;178:112948. doi: 10.1016/j.jpba.2019.112948.
S Akhtartavan 1 M Karimi 1 N Sattarahmady 2 H Heli 3
Affiliations

Affiliations

  • 1 Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
  • 2 Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran. Electronic address: nsattar@sums.ac.ir.
  • 3 Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran. Electronic address: heli@sums.ac.ir.
Abstract

A highly simple, sensitive, specific and low-cost electrochemical apta-cyto-sensor for determination of circulating human MDA-MB-231 breast Cancer cells was fabricated. Non-spherical nanoparticles of gold were electro-deposited in the presence of ethosuximide as a shape directing and size controlling agent. The nanoparticles had dimensions ranging 50-150 nm, and covered the underlying surface with a roughness factor of 8.03. The Non-spherical nanoparticles were then employed as the apta-cyto-sensor transducer. A 83-mer DNA aptamer that is specific to capturing the cell surface proteins was immobilized on the transducer surface, and binding with the cells was followed using the ferro/ferricyanide redox marker. The aptamer was immobilized within ∼200 min on the transducer surface. The cells were quantified with an equation of regression of ΔIp(μA) = (1.028 ± 0.027) log (C (cell mL-1)) + (0.2199 ± 0.0944), a sensitivity of 1.028 μA (log (concentration / cell mL-1))-1 and a quantitation limit of 2 cell mL-1, in a concentration range of 5 to 2 × 106 cell mL-1. The apta-cyto-sensor selectivity was also evaluated toward AsPC-1, Calu-6, HeLa, MCF-7 and melanoma B16/F10 cell lines. The apta-cyto-sensor had a fabrication reproducibility of 4.2%, regeneration capability of 5.1%, a stability of 35 days, and a potential application for the detection of MDA-MB-231 cells in the spiked blood serum samples with a sensitivity of 0.8975 μA (log (concentration / cell mL-1))-1 and a quantitation limit of 5 cell mL-1, in a concentration range of 10 to 1 × 103 cell mL-1. The apta-cyto-sensor would be applicable for breast Cancer diagnosis at early stage.

Keywords

Aptasensor; Breast cancer; Circulating tumor cell; Cytosensor; Point-of-care detection.

Figures
Products